Why is it difficult to switch large-diameter valves? How to solve the problem?

Editor:嘉興美克斯閥門有限公司 │ Release Time:2022-01-12 

Among users who use large-diameter globe valves on a daily basis, they often report a problem that large-diameter globe valves are often difficult to close when they are used in media with a relatively large pressure difference, such as steam, high-pressure water, etc. When closing with force, it is always found that there will be leakage, and it is difficult to close tightly. The reason for this problem is caused by the structural design of the valve and the insufficient output torque of the human limit level.


Analysis of the Difficulty in Switching Large Diameter Valves


The average adult's horizontal limit output force is 60-90kg, depending on different physiques.


Generally, the flow direction of the globe valve is designed to be low in and high out. When a person closes the valve, the human body pushes the handwheel to rotate horizontally, so that the valve flap moves downward to realize the closing. At this time, it is necessary to overcome the combination of three forces, namely :


1) Axial thrust force Fa;


2) Friction force Fb between packing and valve stem;


3) The friction force Fc between the valve stem and the valve disc core


The sum of moments is ∑M=(Fa+Fb+Fc)R


It can be seen that the larger the diameter, the greater the axial thrust force. When it is close to the closed state, the axial thrust force is almost close to the actual pressure of the pipe network (because when it is closed, P1-P2≈P1, P2=0)


For example, a DN200 caliber globe valve is used on a 10bar steam pipe, only the first closing axial thrust Fa=10×πr2=3140kg, and the horizontal circular force required for closing is close to the horizontal circular force that normal human bodies can output. force limit, so it is very difficult for one person to fully close the valve under this condition.


Of course, some factories recommend installing such valves in reverse, which solves the problem of being difficult to close, but there is also the problem that it is difficult to open after closing.


Analysis of the Causes of Internal Leakage of Large Diameter Globe Valves


Large-diameter globe valves are generally used in boiler outlet, main cylinder, steam main and other positions. These positions have the following problems:


1) Generally, the pressure difference at the boiler outlet is relatively large, so the steam flow rate is also larger, and the erosion damage to the sealing surface is also larger. In addition, the combustion efficiency of the boiler cannot be 100%, which will cause the steam at the outlet of the boiler to have a large water content, which will easily cause cavitation and cavitation damage to the valve sealing surface.


2) For the shut-off valve near the boiler outlet and the sub-cylinder, because the steam that has just come out of the boiler has intermittent superheating phenomenon, in the process of its saturation, if the softening treatment of the boiler water is not very good, part of the acid is often precipitated Alkali substances will cause corrosion and erosion to the sealing surface; some crystallizable substances may also adhere to the valve sealing surface and crystallize, resulting in the valve not being able to be tightly sealed.


3) For the inlet and outlet valves of the sub-cylinders, the steam consumption after the valve is large and sometimes small due to production requirements and other reasons. The valve sealing surface causes erosion, cavitation and other damage.


4) Generally, when a large-diameter pipeline is opened, the pipeline needs to be preheated, and the preheating process generally requires a small flow of steam to pass through, so that the pipeline can be heated slowly and evenly to a certain extent before the stop valve can be fully opened to avoid causing the pipeline to rapidly Excessive expansion caused by heating up and damage to some connection parts. However, in this process, the valve opening is often very small, which causes the erosion rate to be far greater than the normal use effect, and seriously reduces the service life of the valve sealing surface.


Solutions to Difficulties in Switching Large Diameter Globe Valves


1) First of all, it is recommended to choose a bellows-sealed globe valve, which avoids the influence of the frictional resistance of the plunger valve and the packing valve, and makes the switch easier.


2) The valve core and seat must be made of materials with good erosion resistance and wear resistance, such as Stellite carbide.


3) It is recommended to adopt a double valve disc structure, which will not cause excessive erosion due to the small opening, which will affect the service life and sealing effect.


主站蜘蛛池模板: 红杏视频打开页 | 精69xxx免费酒店 | 日本中文字幕网 | 一区二区三区四区在线观看视频 | 亚洲美精品二区性爱 | 频道国产在线资源 | 国产日韩精品欧美一区色 | 亚洲欧美日韩中文字幕在线不卡 | 国产又粗又猛又爽又黄的视频吉 | 两性色午夜视频免费播放 | 第一页欧日韩在线视频 | 99re热视频这里只有综合亚洲 | 亚洲精品视在线看1 | 免费人成视频 | 中文字幕国产 | 99999视频精品全部免费 | 日本一本精品中文字幕视频 | 九九线精品视频在线观看视频 | 日本性爱欧美精品 | 水蜜桃成视频人在线看 | 日韩在线一区二区三区观看 | 成人欧美一区二区三区在线 | 国产福利在线永久视频 | 日本一区二区三区在线观看入口 | 99re热这里只有精品66 | 国产亚洲sss在线播放 | 91大神在线精品视频一区 | 高清免费视频一区二区三区 | 日韩在线成年视频人网站观看 | 国产综合色产在线精品 | 亚洲熟女色乱一区二区 | 亚洲欧美日韩在线一区二区三区 | 免费最新电视剧 | 成人区精品一区二区不卡亚 | 国产精品永久免费视频观看 | 国产精品欧美激情一区二区亚洲 | 国产系列丝袜熟女精品网站 | 91精品亚洲国 | 欧洲成人精品高清在线观看 | 亚洲高清国 | 国产在线精品一区二区高清不卡 |